Multi-platform UNIX systems consultant and administrator in mutualized and virtualized environments I have 4.5+ years experience in AIX system Administration field. This site will be helpful for system administrator in their day to day activities.Your comments on posts are welcome.This blog is all about IBM AIX Unix flavour. This blog will be used by System admins who will be using AIX in their work life. It can also be used for those newbies who want to get certifications in AIX Administration. This blog will be updated frequently to help the system admins and other new learners. DISCLAIMER: Please note that blog owner takes no responsibility of any kind for any type of data loss or damage by trying any of the command/method mentioned in this blog. You may use the commands/method/scripts on your own responsibility. If you find something useful, a comment would be appreciated to let other viewers also know that the solution/method work(ed) for you.

Wednesday, 13 August 2014

STEPS TO CONFIGURE CLUSTER


Ø  Define a cluster
Ø  Configure hacmp nodes
Ø  Configure hacmp networks
Ø  Configure hacmp communication interfaces
Ø  Give persistent ip address
Ø  Add on application
Ø  Add a serviceip address
Ø  Create an RG
Ø  Add RG attributes
Ø  Sync the cluster info of node1 to node2
Ø  Start cluster services

CLUSTER MAIN POINTS




TYPES OF CLUSTERS
Active-passive
Active-active
Concurrent multiactive

SERVICE IP
It acts as a alias ip

BOOT IP
Original ip on the interface

PERSISTENT IP
Used for administration purpose

RG POLICIES
Startup
Fail over
Fall back

IP ADDRESS TAKEOVER
Ipat via aliasing
Ipat via replacement

CLUSTER FILESETS
Mentioned in other place

C-SPOC
Provides facility for performing common cluster admin tasks from any node with in cluster

VG ,LV,FS CREATION
Smitty c-spoc

VG TYPES
Nonconcurrent
Concurrent
Enhanced concurrent

CLUSTER SHUTDOWN TYPES
Graceful
Graceful with takeover
Force

RG STATES
Online
Offline
Releasing
Acquiring

Resource group types
Cascading
Rotating
Concurrent

CLUSTER LOG FILES
Hacmp.out
Cluster.log
Cluster.cspoc
Clverify.log
Clcomd.log

CLUSTER DEMONS
clcomdES
clinfoES
clstrmgrES
ctrmc


Dms:
    It is kernel extension which alts the node when enter into the hung state,that extends beyond a certain time limit. It enables the another node in the cluster to acquire the hung node resource in a orderly fashion
Reasons:
·                     Clstrmgr may be starved of cpu
·                     Excessive i/o traffic on a disk
·                     Excessive tcpip traffic over on a interface


Dare:
    Using this we can change the cluster configuration dynamically


Can:
·                     We can add/remove node
·                     We can add/remove interface
·                     We can add/removbe network

Can’t


·                     Changing the cluster name
·                     Changing cluster nodename
·                     Changing rg name

·                     Changing apps server name

DIFFERENCES BETWEEN AIX 5.3 AND 6.1


5.3                                                                              6.1

1.             Default filesysytem type is jfs                               1. Default filesystem type is jfs2
2.             It doesnot contain /admin filesystem                   2. It contains /admin filesystem
3.             Default kernal is 32bit                                             3.default kernal is 64bit
4.             It doesnot support for lpm                                    4.it supports fopr lpm feature
5.             It contains ML mechanisem                                  5. It doesn't contain ML mechanisem
6.             Recent TL is 12                                                       6. Recent TL is 9
7.             We need install nmon feature                              7. Nmon is a default feature init


VIO ACRONYMS


VIO                              :       VIRTUAL INPUT OUTPUT SERVER

LPAR                           :       LOGICAL PARTITION

PPAR                          :       PHYSICAL PARTITION

HMC                            :       HARDWARE MANAGEMENT CONSOLE

DLPAR                        :       DYNAMIC LOGICAL PARTITION

SEA                             :       SHARED ETHERNET ADAPTER

MPIO                           :       MULTI PATH INPUT OUTPUT SERVER

NPIV                            :       NETWORK PORT ID VIRTUALIZATION

LPM                             :       LIVE PARTITION MOBILITY

VLAN                           :       VIRTUAL LOCAL AREA NETWORK

PVID                            :       PORT VLAN ID

FC                               :       FIBER CHANNEL

FSP                             :       FLEXIBLE SERVICE PROCESSOR

SMT                             :       SIMULTAENOUS MULTI THREADING

NVRAM                        :        NON VOLATILE RAM

HEA                             :        HOST ETHERNET ADAPTER

IVE                               :        INTEGRATED VIRTUAL ETHERNET ADAPTER

HA                               :        HIGH AVAILABILITY

CMP                            :        CLUSTER MULTI PROCESSING

C-SPOC                     :        CLUSTER SINGLE POINT OF CONTACT

DMS                            :         DEAD MAN SWITCH

DARE                          :         DYNAMIC AUTOMATIC RECONFIGURATION

DR                               :         DISASTER RECOVERY

ASMI                            :         ADVANCED SYSTEM MANAGEMENT INTERFACE
API                               :         APPLICATION PROGRAMMING INTERFACE
SAN                             :           STORAGE AREA NETWORK
VPD                             :           VITAL PRODUCT DATA
IDE                              :           INTEGRATED DEVICE ELECTRONICS
IPAT                            :           IP ADDRESS TAKEOVER
LUN                             :            LOGICAL UNIT NUMBER
LDAP                           :            LIGHTWEIGHT DIRECT ACCESS PROTOCOL
LED                             :           LIGHT EMITTING DIODE
LMB                             :           LOGICAL MEMORY BLOCK
RDAC                          :           REDUNDANT DISK ARRAY CONTROLLER
RAID                            :           REDUNDANT ARRAY OF INDEPENDENT DISKS
VTD                            :           VIRTUAL TARGET DEVICE


AIX ACRONYMS

AIX ACRONYMS

AIX                              :           ADVANCED INTERACTIVE EXECUTIVE
PV                               :          PHYSICAL VOLUME
VG                              :          VOLUME GROUP
PP                               :          PHYSICAL PARTITION
LP                               :          LOGICAL PARTITION
LV                               :          LOGICAL VOLUME
LVM                            :          LOGICAL VOLUME MANAGEMENT
FS                               :          FILE SYSTEM
JFS                             :          JOURNALED FILE SYSTEM
JFS2                           :          ENHANCED  JOURNALED FILE SYSTEM
CDRFS                      :          CDROM FILESYSTEM
GPFS                         :          GENERAL PARALLEL FILE SYSTEM
PS                               :          PAGING SPACE
NFS                            :          NETWORK FILESYSTEM
RG                              :          RESOURCE GROUP
RPC                            :          REMOTE PROCEDURE CALL
APAR                         :          AUTHORIZED PROGRAM ANALYSIS REPORT
PTF                             :          PROGRAM TEMPORARY FIX
ODM                           :          OBJECT DATA MANAGER
TL                                :          TECHNOLOGY LEVEL
ML                               :           MAINTANENCE LEVEL
NIM                             :          NETWORK INSTALLATION MANAGEMENT
ADM                           :          ALT DISK MANAGEMENT
SSH                            :           SECURE SHELL
TCPIP                         :          TRANMISSION CONTROL PROTOCOL/INTERNET PROTOCOL
LTG                             :          LOGICAL TRACK GROUP
SPOT                         :            SHARED PRODUCT OBJECT TREE
LPP                            :             LICENSED PROGRAM PRODUCT
RPM                           :            REDHOT PACKAGING MANAGER
POST                         :           POWER ON SELF TEST
ARP                            :          ADDRESS RESOLUTION PROTOCOL
VGDA                         :            VOLUME GROUP DESCRIPTOR AREA
VGSA                         :           VOLUME GROUP STATUS AREA

BOS                            :           BASE OPERATING SYSTEM